[Example] Store the parameters read out from the inverter, in the EEPROM inside the digital operator
.
*1 When READ is enabled (n177=1), this setting is not necessary.
*2 The setting is not necessary unless the READ prohibition is selected.
Explanation
Operator display
• Enable the setting of the
parameters n001 to n179.
• Set parameter read prohibited
selection (n177) to read
enabled. *1
• Execute read-out (READ) by
parameter copy function
selection (n176).
• Set Parameter read prohibited
selection (n177) to READ
disabled. *2.
• Press DSPL to light [PRGM].
• Press ENTER to display the set
value.
• Change the set value to 4 by
pressing
or
key.
• Press ENTER.
• Change the parameter No. to
n177 by pressing
or
key.
• Press ENTER to display the set
value.
• Change the set value to 1 by
pressing
or
key.
• Press ENTER.
• Change the parameter No. by
pressing
or
key.
• Press ENTER to display the set
value.
• Change the set value to rEd by
pressing
or
key.
• Press ENTER.
• Press DSPL or ENTER
• Change the parameter No. to
n177by pressing
or
key.
• Press ENTER to display the set
value.
• Change the set value to 0 by
pressing
or
key.
• Press ENTER.
(Can be a different parameter No.)
( Lit )
(Can be a different set value.)
(Blinks)
(Lit for one second.)
(The parameter is
displayed)
( Lit )
(Blinks)
(Lit for one second)
(The parameter displayed)
(Lit)
(Lit)
(Blinks while executing
READ)
(End is displayed after the
execution of READ is completed.)
(The parameter is
displayed.)
(Lit)
( Blinks )
( Lit for one minute )
(The parameter No. is
displayed.)