Specifications, Standard specifications (200v), Standard specifications (200v class) – IDEX Health & Science VS-606V7 Series User Manual
Page 139

139
9. Specifications
•
Standard Specifications (200V Class)
Voltage Class
200V single- / 3-phase
Model
CIMR-V7*C
‰‰‰‰
3-phase
20P1 20P2 20P4 20P7 21P5 22P2 23P7 25P5 27P5
Single-phase
B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B3P7
-
-
Max. Applicable Motor Output kW*
0.1
0.25
0.55
1.1
1.5
2.2
3.7
5.5
7.5
Ou
tp
u
t
Ch
arac
te
ri
s
ti
c
s
Inverter Capacity (kVA)
0.3
0.6
1.1
1.9
3.0
4.2
6.7
9.5
13
Rated Output Current (A)
0.8
1.6
3
5
8
11
17.5
25
33
Max. Output Voltage (V)
3-phase, 200 to 230V (proportional to input voltage)
Single-phase, 200 to 240V (proportional to input voltage)
Max. Output Frequency (Hz)
400 Hz (Programmable)
Input
Current (A)
(3-Phase)
1.1
1.9
3.9
6.4
11.0
15.1
24.0
33.0
39.6
(Single-Phase)
1.8
3.7
7.4
12.8
20.5
24.0
40.0
-
-
Po
w
e
r
S
uppl
y
Rated Input Voltage and
Frequency
3-phase, 200 to 230V, 50/60Hz
Single-phase, 200 to 240V, 50/60Hz
Allowable Voltage Fluctuation
-15 to +10%
Allowable Frequency Fluctuation
±
5%
Co
nt
rol
Charac
te
ri
s
ti
c
s
Control Method
Sine wave PWM (V/f control/voltage control selectable)
Frequency Control Range
0.1 to 400Hz
Frequency Accuracy
(Temperature Change)
Digital reference:
±
0.01% (-10 to +50
°
C)
Analog reference:
±
0.5% (25
±
10
°
C)
Frequency Setting Resolution
Digital reference:
0.01Hz (less than 100Hz) / 0.1Hz (100Hz or more)
Analog reference: 1 / 1000 of max. output frequency
Output Frequency Resolution
0.01Hz
Overload Capacity
150% rated output current for one minute
Frequency Reference Signal
0 to 10VDC (20k
Ω
), 4 to 20mA (250
Ω
), 0 to 20mA (250
Ω
)
pulse train input, frequency setting potentiometer
(Selectable)
Accel/Decel Time
0.00 to 6000 sec.
(accel/decel time are independently programmed)
Braking Torque
Short-term average deceleration torque‡
0.1, 0.25kW (0.13HP, 0.25HP): 150%
0.55, 1.1kW (0.5 HP, 1HP): 100%
1.5kW (2HP): 50%
2.2kW(3HP) or more: 20%
Continuous regenerative torque: Approx. 20% (150% with
optional braking resistor, braking transistor built-in)
V/f Characteristics
Possible to program any V/f pattern
*
Based on a standard 4-pole motor for max. applicable motor output.
‡
Shows deceleration torque for uncoupled motor decelerating from 60Hz
with the shortest possible deceleration time.