IDEX Health & Science VS-606V7 Series User Manual
Page 158
158
070
0146
Analog frequency
reference filter time
parameter (CN2 V
in
)
0.00 to 2.00s
0.01s
0.10s
79
071
0147
Analog frequency
reference gain
(CN2 I
in
)
-255 to 255%
1%
100%
79
072
0148
Analog frequency
reference bias
(CN2 I
in
)
-100 to 100%
1%
0%
79
073
0149
Analog frequency
reference filter time
parameter
(CN2 I
in
)
0.00 to 2.00s
0.01s
0.01s
---
074
014A
Pulse train frequency
reference gain (RP)
0 to 255%
1%
100%
79
075
014B
Pulse train frequency
reference bias (RP)
-100 to 100%
1%
0%
79
076
014C
Pulse train frequency
filter time parameter
(RP)
0.00 to 2.00s
0.01s
0.10s
---
077
#2
014D
Multifunction analog
input selection
0 to 4
1
0
78
078
#2
014E
Multifunction analog
input signal selection
0,1
1
0
81
079
#2
014F
Frequency reference
bias (FBIAS) value
0 to 50%
0.1%
10%
81
No.
Register
No. for
Trans-
mission
Name
Setting Range
Setting
Unit
Initial
Setting
User
Setting
Ref.
Page