IDEX Health & Science VS-606V7 Series User Manual
Page 101
101
* Communications error contents are saved until fault reset is input. (Reset is enabled during run.)
Register No.
bit
Description
02EH
In
v
e
rt
er S
tat
us
0
Frequency ref. loss
1
Not used
2
Not used
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
8 - F
Not used
002FH-0030H
Reserved
0031H
Main circuit DC voltage (1/1V)
0032H
Torque monitor
0033H-0034H
Not used
0035H
Cumulative operation time (I/IH)
0036H
Not used
Register No.
bit
Description
0037H
Output power (1/1W : with sign)
0038H
PID feedback value (100% / Input equivalent to max. output frequency; 10/1%; without sign)
0039H
PID input value (±100% / ± Max. output frequency ; 10/1%; with sign)
003AH
PID output value (±100% / ± Max. output frequency ; 10/1%; with sign)
003BH-003CH
Reserved
003DH
Com
m
un
ic
at
io
ns
error
0
CRC error
1
P1 “ON”
2
(Not used)
3
Parity error
4
Overrun error
5
Framing error
6
Timeover
7
(Not used)
003EH-00FFH
Reserved