The energy-saving coefficient K2 (n140) is set to a value that corresponds with that
motor code (n158).
Motor Code
Motor Type
Voltage Class
Capacity
Motor Code: n158
Energy-saving
coefficient K2: n140
YASKAWA
General-
purpose
Motor
200V
0.1 kW
0
481.7
0.2 kW
1
356.9
0.4 kW
2
288.2
0.75 kW
3
223.7
1.5 kW
4
169.4
2.2 kW
5
156.8
3.7 kW
7
122.9
5.5 kW
9
94.8
7.5 kW
10
72.7
400V
0.2 kW
21
713.8
0.4 kW
22
576.4
0.75 kW
23
447.4
1.5 kW
24
338.8
2.2 kW
25
313.6
3.0 kW
26
245.8
3.7 kW
27
245.8
5.5 kW
29
189.5
7.5 kW
30
145.4
YASKAWA
Inverter
Motor
200V
0.1 kW
40
481.7
0.2 kW
41
356.9
0.4 kW
42
300.9
0.75 kW
43
224.7
1.5 kW
44
160.4
2.2 kW
45
138.9
3.7 kW
47
106.9
5.5 kW
49
84.1
7.5 kW
50
71.7
400V
0.2 kW
61
713.8
0.4 kW
62
601.8
0.75 kW
63
449.4
1.5 kW
64
320.8
2.2 kW
65
277.8
3.0 kW
66
213.8
3.7 kW
67
213.8
5.5 kW
69
168.3
7.5 kW
70
143.3