Speed search command
Restarts a coasting motor without stopping it. This function enables smooth
switching between motor commercial power supply operation and inverter
operation.
Set input terminal function selection (n050 to n056) to “14” (search command from
maximum output frequency) or “15” (search command from set frequency).
Build a sequence so that FWD (REV) run command is input at the same time as the
search command or after the search command. If the run command is input before
the search command, the search command becomes disabled.
•
Time chart at search command input
Set declaration time during a speed search at parameter n101. Speed search starts
when inverter output current
>
speed search operation level.
This function applies to the 200/400V class 7.5/10hp inverters.