IDEX Health & Science VS-606V7 Series User Manual
Page 169
169
Recommended Line Filters for VS-606V7 made by Rasmi Electronic Ltd
( 200 V three phase)
Rated Voltage: AC 250V three phase
Ambient Temperature: 40×C (max.)
Recommended Line Filters for VS-606V7 made by Rasmi Electronic Ltd
( 400 V three phase)
Rated Voltage: AC 480V three phase
Ambient Temperature: 40×C (max.)
VS-606V7
Model
Current
(A)
Weight
(kg)
Dimension
W
×
D
×
H
CIMR-V7AU20P1
CIMR-V7AU20P2
RS 2010-V7
10
0.8
82 x 50 x 194
CIMR-V7AU20P4
CIMR-V7AU20P7
CIMR-V7AU21P5
RS 2020-V7
16
1.0
111 x 50 x 169
CIMR-V7AU22P2
CIMR-V7AU23P7
RS 2030-V7
26
1.1
144 x 50 x 174
VS-606V7
Model
Current
(A)
Weight
(kg)
Dimension
W
×
D
×
H
CIMR-V7AU40P2
RS 3005-V7
5
1.0
111 x 45 x 169
CIMR-V7AU40P4
CIMR-V7AU40P7
CIMR-V7AU41P5
RS 3010-V7
10
1.0
111 x 45 x 169
CIMR-V7AU42P2
CIMR-V7AU43P7
RS 3020-V7
20
1.1
144 x 50 x 174