IDEX Health & Science VS-606V7 Series User Manual
Page 166
166
•
200V class single-phase
•
400V class 3-phase
* Values of motor line-to-line resistance are set to half of the standard value.
= Values between V/f mode and Vector control mode.
No.
Name
Unit
Factory setting
–
Inverter capacity
kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW –
3.7kW 5.5kW 7.5kW
n036 Motor rated current
A
0.6
1.1
1.9
3.3
6.2
8.5
–
14.1
9.8
13.3
n105
Torque
compensation iron
loss
W
1.7
3.4
4.2
6.5
11.1
11.8
–
19
28.8
43.9
n106 Motor rated slip
Hz
2.5
2.6
2.9
2.5
2.6
2.9
–
3.3
1.5
1.3
n107
Motor resistance for
one phase*
Ω
17.99
10.28
4.573
2.575
1.233
0.8
–
0.385
0.797
0.443
n108
Motor leak
inductance
MH
110.4
56.08
42.21
19.07
13.4
9.81
–
6.34
16.87
10.59
n110
Motor no-load
current
%
72
73
62
55
45
35
–
32
26
30
No.
Name
Unit
Factory setting
–
Inverter capacity
kW
– 0.37kW 0.55kW 1.1kW 1.5kW 2.2kW 3.0kW 3.7kW 5.5kW 7.5kW
n036 Motor rated current
A
–
0.6
1.0
1.6
3.1
4.2
7.0
7.0
9.8
13.3
n105
Torque
compensation iron
loss
W
–
3.4
4.0
6.1
11.0
11.7
19.3
19.3
28.8
43.9
n106 Motor rated slip
Hz
–
2.5
2.7
2.6
2.5
3.0
3.2
3.2
1.5
1.3
n107
Motor resistance for
one phase*
Ω
–
41.97
19.08
11.22
5.044
3.244
1.514
1.514
0.797
0.443
n108
Motor leak
inductance
MH
–
224.3
168.8
80.76
53.25
40.03
24.84
24.84
16.87
10.59
n110
Motor no-load
current
%
–
73
63
52
45
35
33
33
26
30