beautypg.com

IDEX Health & Science VS-606V7 Series User Manual

Page 166

background image

166

200V class single-phase

400V class 3-phase

* Values of motor line-to-line resistance are set to half of the standard value.
= Values between V/f mode and Vector control mode.

No.

Name

Unit

Factory setting

Inverter capacity

kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW –

3.7kW 5.5kW 7.5kW

n036 Motor rated current

A

0.6

1.1

1.9

3.3

6.2

8.5

14.1

9.8

13.3

n105

Torque
compensation iron
loss

W

1.7

3.4

4.2

6.5

11.1

11.8

19

28.8

43.9

n106 Motor rated slip

Hz

2.5

2.6

2.9

2.5

2.6

2.9

3.3

1.5

1.3

n107

Motor resistance for
one phase*

17.99

10.28

4.573

2.575

1.233

0.8

0.385

0.797

0.443

n108

Motor leak
inductance

MH

110.4

56.08

42.21

19.07

13.4

9.81

6.34

16.87

10.59

n110

Motor no-load
current

%

72

73

62

55

45

35

32

26

30

No.

Name

Unit

Factory setting

Inverter capacity

kW

– 0.37kW 0.55kW 1.1kW 1.5kW 2.2kW 3.0kW 3.7kW 5.5kW 7.5kW

n036 Motor rated current

A

0.6

1.0

1.6

3.1

4.2

7.0

7.0

9.8

13.3

n105

Torque
compensation iron
loss

W

3.4

4.0

6.1

11.0

11.7

19.3

19.3

28.8

43.9

n106 Motor rated slip

Hz

2.5

2.7

2.6

2.5

3.0

3.2

3.2

1.5

1.3

n107

Motor resistance for
one phase*

41.97

19.08

11.22

5.044

3.244

1.514

1.514

0.797

0.443

n108

Motor leak
inductance

MH

224.3

168.8

80.76

53.25

40.03

24.84

24.84

16.87

10.59

n110

Motor no-load
current

%

73

63

52

45

35

33

33

26

30