Decreasing motor speed fluctuation, Slip compensation (when v/f control mode n002=0) – IDEX Health & Science VS-606V7 Series User Manual
Page 89
89
•
Decreasing Motor Speed Fluctuation
As the load becomes larger, motor speed is reduced and motor slip value is increased.
The slip compensating function controls the motor speed at a parameter value even if
the load varies.
When inverter output current is equal to the motor rated current (n036), the
compensation frequency is added to the output frequency.
Related Parameters
* Differs depending on inverter capacity.
Notes: 1.
Slip compensation is not performed in the following condition:
Output frequency < minimum output frequency (n016).
2.
Slip compensation is not performed during regeneration.
3.
Slip compensation is not performed when motor rated current (n036) is
set to 0.0A.
Slip compensation (When V/f control mode n002=0)
Parameters
No.
Name
Unit
Setting Range
Initial
Setting
n036
Motor rated current
0.1A 0 to 150% of inverter rated current
*
n111
Slip compensation gain
0.1
0.0 to 2.5
0.0
n110
Motor no-load current
1%
0 to 99% (100% = Motor rated current n036)
*
n112
Slip compensation primary
delay time
0.1s
0.0 to 25.5s
When 0.0s is set, delay time becomes 2.0s.
2.0s
n106
Motor rated slip
0.1Hz 0.0 to 20Hz
*
Compensation frequency
Motor rated slip (n106)
=
Output current
Motor no-load current (n110)
–
Electronic thermal
reference current (n036)
Motor no-load current (n110)
–
---------------------------------------------------------------------------------------------------------------------------------------------------
×
Slip compensation gain (n111)
Ч