IDEX Health & Science VS-606V7 Series User Manual
Page 144
![background image](/manuals/545233/144/background.png)
144
O
th
e
r F
u
nc
ti
ons
Di
spl
a
y
Status Indicator LED
RUN and ALARM provided as standard LEDs
Digital Operator
(JVOP-140)
Available to monitor frequency reference, output
frequency, output current
Terminals
Main circuit: screw terminals
Control circuit: plug-in screw terminal
Wiring Distance between
Inverter and Motor
328ft (100m) or less#
Enclosure
Open chassis IP20, Open chassis IP20 (Top-closed type),
or enclosed wall-mounted NEMA 1
Cooling Method
Cooling fan is provided for the following models: 400V,
1.5kW or larger inverters (3-Phase)
Others models are self-cooling
E
n
v
iron
m
ent
al
Con
d
it
ions
Ambient Temperature
Open chassis IP20 : -10 to +50
°
C (14 to 122
°
F)
Open chassis IP20 (Top-closed type) and enclosed
wall mounted NEMA1. : -10 to +40
°
C (14 to 105
°
F)
(not frozen)
Humidity
95% RH or less (non-condensing)
Storage Temperature*
-4 to 140
°
F (-20 to +60
°
C)
Location
Indoor (free from corrosive gases or dust)
Elevation
3280ft (1000m) or less
Vibration
Up to 9.8m / S
2
(1G) at less than 20Hz, up to 2m / S
2
(0.2G) at less than 20 to 50Hz
* Temperature during shipping (for short period)
# For details, refer to “Reducing motor noise or leakage current (n080)” on
page 68.
Voltage Class
400V 3-phase
Model
CIMR-V7*C
‰‰‰‰
3-phase
40P2 40P4 40P7 41P5 42P2 43P0 43P7 45P5 47P5
Single-phase
–
–
–
–
–
–
–
–
–