Pid output gain (n163), Pid feedback value adjusting gain (n129) – IDEX Health & Science VS-606V7 Series User Manual
Page 113
113
•
PID Output Gain (n163)
This parameter adjusts the output gain.
•
PID Feedback Value Adjusting Gain (n129)
Parameter n129 is the gain that adjusts the feedback value.
•
PID Feedback Loss Detection (n136, n137, n138)
Parameter
No.
Name
Unit
Setting
Range
Initial
Setting
n163
PID Output gain
Multiples
0.0 to 25.0
1.0
Parameter
No.
Name
Unit
Setting
Range
Initial
Setting
n129
PID feedback value
adjusting gain
Multiples
0.0 to 10.0
1.00
Parameter
No.
Name
Unit
Setting
Range
Initial
Setting
n136
Selection of PID
feedback loss detection
-
0: No detection of PID
feedback loss
1: Detection of PID
feedback loss
(Operation
continued: FbL
alarm)
2: Detection of PID
feedback loss
(Output shut down:
fault)
0
n137
PID feedback loss
detection level
%
0 to 100
100%/Max. output
frequency
0
n138
PID feedback loss
detection time
%
0.0 to 25.5
1.0