IDEX Health & Science VS-606V7 Series User Manual
Page 164

164
151
0197
Timeover detection
selection
0 to 4
1
0
94
152
0198
Setting unit selection of
communications
frequency reference/
frequency monitor
0, 1, 2, 3
1
0
94
153
0199
Slave address
0 to 32
1
0
94
154
019A
Baud rate selection
0 to 3
1
2
94
155
019B
Parity selection
0, 1, 2
1
2
94
156
019C
Send waiting time
10 to 65ms
1ms
10ms
94
157
019D
RTS control
0, 1
1
0
94
158
019E
Motor code (energy-
saving control)
0 to 70
1
(Note 7)
105
159
019F
Energy-saving voltage
upper limit (at 60Hz)
0 to 120%
1%
120%
106
160
01A0
Energy-saving voltage
upper limit (at 6Hz)
0 to 25%
1%
16%
106
161
01A1
Search operation power
detection hold width
0 to 100%
1%
10%
108
162
01A2
Power detection filter
time parameter
0 to 255
1 = 4 ms
5 (20ms)
108
163
01A3
PID output gain
0.0 to 25.0
0.1
1.0
113
164
01A4
PID feedback selection
0 to 5
1
0
110
165
01A5
Overheat protect select
for installed braking
resistor (Note 9)
0,1
1
0
61
166
01A6
Input open-phase
detection level (Note 9)
0 to 100%
1%
0%
---
167
01A7
Input open-phase
detection time (Note 9)
0 to 255,s
1,s
0,s
---
168
01A8
Output open-phase
detection level (Note 9)
0 to 100%
1%
0%
---
169
01A9
Input open-phase
detection time (Note 9)
0 to 2,0,s
0.1,s
0.0,s
---
175
#1
#2
01AF
Reducing carrier
frequency selection at
low speed
0,1
1
0
(Note 10)
70
176
01B0
Parameter copy
selection
rdy,rEd,CPy
vFy,vA,Sno
---
rdy
116
177
01B1
Prohibiting parameter
read selection
0,1
1
0
117
178
01B2
Fault history
Stores,
displays most
recent 4
alarms
Setting
disabled
–
36
179
01B3
Software No.
Displays lower-
place 4 digits
of software No.
Setting
disabled
–
–
No.
Register
No. for
Trans-
mission
Name
Setting Range
Setting
Unit
Initial
Setting
User
Setting
Ref.
Page