Horner APG XL6 OCS User Manual
Page 67
MAN0883-05-EN
CH.12
March 4, 2010
Page 67 of 135
#1037
View Protocols
The View Protocols Sub-Menu displays two System Settings, neither of which are editable.
As mentioned in 0, both the MJ1 (Port 1) and MJ2 (Port 2) serial ports support downloadable protocols.
To assign a downloadable protocol to an XL6 OCS serial port, select the Protocol Config item in
Cscape’s Program menu and then setup a protocol for Port 1 or Port 2 (or both).
In the View Protocols Sub-Menu, the currently downloaded protocol, if any, and its version number are
displayed for both Port 1 and Port 2.
Port 1:
Protocol name
= (None Loaded) or name of the protocol assigned to MJ1
Protocol version
= Blank or version of the protocol assigned to MJ1
Port 2:
Protocol name
= (None Loaded) or name of the protocol assigned to MJ2
Protocol version
= Blank or version of the protocol assigned to MJ2
Set Fkeys Mode
The Set Fkeys Sub-Menu displays two System Settings, both of which are editable.
Fkeys:
Momentary
= %K1-10 bits go On & Off as F1-F10 are pressed & released
Toggle
= %K1-10 bits toggle each time F1-F10 are pressed
SYS_Fn enable:
Yes
= Reset and all clear system functions enabled
No
= Reset and all clear system functions disabled