#1037

Error

A high indication on this register (%I31) indicates that one of the analog parameters
specified above is invalid or the stepper action was aborted before the operation was
complete. This register is cleared on the next start command if the error was corrected.


The stepper requires one discrete register (%Q1) to control the stepper action. Setting this
register starts the stepper cycle. This register must remain set to complete the entire cycle.
Clearing this register before the cycle is complete aborts the step sequence and sets the error bit.

Note that setting the PLC mode to Stop while the stepper is in operation causes the
stepper output to immediately drop to zero and the current stepper count to be lost.

Note that stepper output level may cause damage or be incompatible with some motor
driver inputs. Consult drive documentation to determine if output level and type is
compatible.

11.5

PWM functions register map

Register

PWM

HSC

Stepper

%AQ1 Start

Frequency

%AQ2

PWM1 Duty Cycle (32-

bit)

HSC1

Preset Value

Run Frequency

%AQ3
%AQ4

PWM2 Duty Cycle (32-

bit)

HSC2

Preset Value

Accel Count

(32-bit)

%AQ5
%AQ6

PWM Prescale

(32-bit)

Run Count

(32-bit)

%AQ7
%AQ8

PWM Period

(32-bit)

Decel Count

(32-bit)

%Q1

Run

%I30 Ready/Done
%I31

Error


11.6

PWM Examples


All of the PWM examples use the following formula.

Frequency =

(

)

t

PeriodCoun

escale

×

+1

Pr

000

,

000

,

16

Example 1
To get a 50% Duty Cycle @ 10 kHz waveform on PWM1:

Set %AQ1-2 = 50 (duty cycle count)
Set %AQ5-6 = 15 (prescale count)
Set %AQ7-8 = 100 (period count)

Example 2
To get a 50% Duty Cycle on PW1 and 90 % Duty Cycle on PWM2 @ 1 kHz waveform:

Set %AQ1-2 = 500 (duty cycle count)
Set %AQ3-4 = 900 (duty cycle count)
Set %AQ5-6 = 15 (prescale count)
Set %AQ7-8 = 1000 (period count)