beautypg.com

Pf3000 pro cotton yield monitor, Ag leader technology, Gps setup – Ag Leader PF3000Pro Cotton Yield Monitor Operators Manual User Manual

Page 45

background image

PF3000 Pro Cotton Yield Monitor

Ag Leader Technology

GPS Setup

July 2003

2-31








BEACON SETUP

Mode:

Manual

Channel 0 Frequency

300.0

Channel 1 Frequency

300.0

ACCEPT

EXIT


Step

Action

5

If you are setting to Manual push ACCEPT key then use
down arrow key to scroll to Channel 0 Frequency and
press EDIT key. Use the up or down arrow key to set
desired frequency and press ACCEPT key. Scroll down
to Channel 1 Frequency and press EDIT key. Use up or
down arrow keys to set desired frequency and press
ACCEPT key.

6

Press the EXIT key two times to return to operating
screen.