PF3000 Pro Cotton Yield Monitor

Sensor Setup

Ag Leader Technology

July 2003

2-28

Zero Flow
Threshold

The zero flow threshold affects both the stringer and choke alarms. It
can be adjusted from 0 to 65000, but typical settings are within the
range of 50 to 500. The zero flow threshold sets the amount of flow
which is considered negligible. When driving your picker around, you
may see very small but non-zero flow readings in the Sensor Data
Diagnostics. This threshold should be set larger than the average of
these non-zero readings to avoid false stringer and choke alarm
activations.























Flow Sensor
Firmware

To view the flow sensor firmware version, highlight the Flow Sensor
Firmware Update line and press EDIT. Highlight the setting to be
changed and press the EDIT key. Press the UP or DOWN ARROW
keys to select the setting to be changed and press the EDIT key. Use
the UP or DOWN ARROW keys to change the number value and
press the ACCEPT key. Press the EXIT key when the sensors are set.