beautypg.com

Pf3000 pro cotton yield monitor, Ag leader technology – Ag Leader PF3000Pro Cotton Yield Monitor Operators Manual User Manual

Page 22

background image

PF3000 Pro Cotton Yield Monitor

Vehicle Setup

Ag Leader Technology

July 2003

2-8

NOTE: If you want to use a radar gun, contact an Ag Leader Technology
dealer and purchase a special adapter cable for your radar gun.

Custom
Configuration

This screen allows you to define where the sensors are located. On the
Vehicle Setup screen you defined the make, configuration and the number
of rows sensed. The CUSTOM configuration is defined on this screen.

The number of rows displayed on this screen is defined by the Picker
Configuration. The choices are limited by the Picker Make. Options will
vary between picker and cotton strippers.

The Picker Configuration & Flow Sensor Configuration define the default
sensor locations. For example:

4-Row Picker / 2 Rows: Row 1 and 4 are defined as INSTALLED.
5-Row Picker / 2 Rows: Row 1 and 5 are defined as INSTALLED.
6 Row Picker / 2 Rows: Row 2 and 5 are defined as INSTALLED.
2, 4, 5, 6 Row Picker / All Rows: All Rows are defined as INSTALLED.

NOTE: For CASE-IH Pickers the choices are NONE,
FRONT/REAR and FRONT ONLY. For Deere Pickers the choices
are NONE and INSTALLED.