beautypg.com

Pf3000 pro cotton yield monitor, Ag leader technology, Flow sensor alarms – Ag Leader PF3000Pro Cotton Yield Monitor Operators Manual User Manual

Page 110

background image

PF3000 Pro Cotton Yield Monitor

Flow Sensor Alarms

Ag Leader Technology

July 2003

4-32


Introduction


The flow sensor alarms warn you when one or more flow sensors are not
operating. The types of alarms are Communications, Low Signal, Stringer
and Choke.

Alarm Activation

The activation of the alarm will be by a buzzer sounding and a full screen
message telling you which sensors are not sending data to the yield monitor.
Simply note which sensors are reporting and press the CANCEL key.

Communications
Alarm

This alarm warns you to sensors that are not operating properly resulting in
lost yield data. The example below shows sensor communication alarms for
sensors 1 and 4 for a Case-IH picker

COTTON SENSOR ERROR

ALARM CONDITION

FLOW SENSOR NOT RESPONDING

1F

4R



CHECK FLOW SENSOR

CANCEL