beautypg.com

Expand pool wizard, Expand pool window – HP XP P9500 Storage User Manual

Page 262

background image

Description

Item

Displays the Smart Tiers or Smart Tiers Z information.

Smart Pool

Monitoring Mode

If the continuous mode is enabled, Continuous Mode is displayed. If the
period mode is enabled, Period Mode is displayed.

Tier Management

If Smart Tiers or Smart Tiers Z is enabled, Auto or Manual of performance
monitoring and tier relocation is displayed. If Smart Tiers or Smart Tiers Z is
disabled, a hyphen (-) is displayed.

Cycle Time

Displays the cycle of performance monitoring and tier relocation. If Smart
Tiers or Smart Tiers Z is disabled, a hyphen (-) is displayed.

Monitoring Period

Displays the time zone of performance monitoring when 24 Hours is selected
in the Cycle Time list. If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-)
is displayed.

Displays the information of the buffer space for new page assignment to each
tier.

Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the
buffer space for new page assignment to tier 1 is displayed. If you make the
Smart Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.

Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 2 exists, the buffer space for new page assignment to tier 2 is displayed.
If you make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2
does not exist, a hyphen (-) is displayed.

Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 3 exists, the buffer space for new page assignment to tier 3 is displayed.
If you make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3
does not exist, a hyphen (-) is displayed.

Buffer Space for New page
assignment (%)

Displays the information of the buffer space for tier relocation to each tier.

Buffer Space for Tier relocation (%)

Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the
buffer space for tier relocation to tier 1 is displayed. If you make the Smart
Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.

Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 2 exists, the buffer space for tier relocation to tier 2 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not
exist, a hyphen (-) is displayed.

Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 3 exists, the buffer space for tier relocation to tier 3 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3 does not
exist, a hyphen (-) is displayed.

Displays the Pool Properties window when a row is selected, and shows the
error window when a row is not selected or multiple rows are selected.

Detail

NOTE:

Information in this topic assumes that only a single task is executed. If multiple tasks are

executed, this window displays all configuration items. To check information for a configuration
item, click Back to return to each configuration window, and then click Help.

Expand Pool wizard

Expand Pool window

Use this window to add LDEVs to a pool to expand the pool to increase pool capacity.

262 Thin Provisioning Z and Smart Tiers Z GUI reference