Expand pool wizard, Expand pool window – HP XP P9500 Storage User Manual
Page 262
Description
Item
Displays the Smart Tiers or Smart Tiers Z information.
Smart Pool
•
Monitoring Mode
If the continuous mode is enabled, Continuous Mode is displayed. If the
period mode is enabled, Period Mode is displayed.
•
Tier Management
If Smart Tiers or Smart Tiers Z is enabled, Auto or Manual of performance
monitoring and tier relocation is displayed. If Smart Tiers or Smart Tiers Z is
disabled, a hyphen (-) is displayed.
•
Cycle Time
Displays the cycle of performance monitoring and tier relocation. If Smart
Tiers or Smart Tiers Z is disabled, a hyphen (-) is displayed.
•
Monitoring Period
Displays the time zone of performance monitoring when 24 Hours is selected
in the Cycle Time list. If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-)
is displayed.
Displays the information of the buffer space for new page assignment to each
tier.
•
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the
buffer space for new page assignment to tier 1 is displayed. If you make the
Smart Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.
•
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 2 exists, the buffer space for new page assignment to tier 2 is displayed.
If you make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2
does not exist, a hyphen (-) is displayed.
•
Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 3 exists, the buffer space for new page assignment to tier 3 is displayed.
If you make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3
does not exist, a hyphen (-) is displayed.
Buffer Space for New page
assignment (%)
Displays the information of the buffer space for tier relocation to each tier.
Buffer Space for Tier relocation (%)
•
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the
buffer space for tier relocation to tier 1 is displayed. If you make the Smart
Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.
•
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 2 exists, the buffer space for tier relocation to tier 2 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not
exist, a hyphen (-) is displayed.
•
Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and
tier 3 exists, the buffer space for tier relocation to tier 3 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3 does not
exist, a hyphen (-) is displayed.
Displays the Pool Properties window when a row is selected, and shows the
error window when a row is not selected or multiple rows are selected.
Detail
NOTE:
Information in this topic assumes that only a single task is executed. If multiple tasks are
executed, this window displays all configuration items. To check information for a configuration
item, click Back to return to each configuration window, and then click Help.
Expand Pool wizard
Expand Pool window
Use this window to add LDEVs to a pool to expand the pool to increase pool capacity.
262 Thin Provisioning Z and Smart Tiers Z GUI reference