HP XP P9500 Storage User Manual
Page 165
If an error occurs during the operations, the error code and error message appear in the error
message dialog box. For more information about error messages, see the HP XP P9000 Remote
Web Console Messages.
Troubleshooting provisioning while using RAID Manager
If an error occurs while operating Data Retention or Thin Provisioning Z while using RAID Manager,
you might identify the cause of the error by referring to the log appearing on the RAID Manager
window or the RAID Manager operation log file.
The RAID Manager operation log file is stored in the following directory.
/HORCM/log*/curlog/horcmlog_HOST/horcm.log
where
•
* is the instance number.
•
HOST is the host name.
The following is an example of a log entry in the RAID Manager window.
Errors when operating RAID Manager (Thin Provisioning Z, SSB1: 0x2e31/0xb96d)
Solutions
Error Contents
Error Code (SSB2)
Perform user authentication.
The command cannot be executed because user
authentication is not performed.
0x9100
Ask HP Technical Support to solve the problem.
Error occurred when increasing THP V-VOL
capacity operation.
0xb900/ 0xb901/
0xaf28
Increase the THP V-VOL capacity after finishing
operations on your storage system, such as the
The operation was rejected because the
configuration was being changed by SVP or
0xb902
Virtual LVI operation or a maintenance
Remote Web Console, or because the THP
operation. See Caution in
increasing THP V-VOL capacity” (page 58)
.
V-VOL capacity was going to be increased by
another instance of the RAID Manager.
Increase the THP V-VOL capacity after the
specified volume is placed online with an OS
which supports EAV.
The operation was rejected because the
specified volume is placed online with the OS
which does not support EAV (Extended Address
Volume).
0xaf22
Specify a capacity so that the pool reservation
rate will not be exceeded.
The operation was rejected because the total
THP V-VOL capacity exceeded the pool
0xaf24
reservation rate after the capacity was
increased.
Check the emulation type of the specified THP
V-VOL.
The operation to increase capacity cannot be
performed on the specified THP V-VOL.
0xaf25
Specify a capacity so that the maximum number
of Pool Volumes (cache management devices)
will not be exceeded.
The operation was rejected because of lack of
cache management devices due to increased
capacity.
0xaf26
Makes sure that the volume is a THP V-VOL.
Because the specified volume was not a THP
V-VOL, the operation was rejected.
0xaf29
To increase capacity, specify a capacity that
does not exceed the value immediately below
Because the specified capacities are invalid or
exceeded the value immediately below LDEV
0xaf2a
LDEV Capacity in the Expand Virtual Volumes
Capacity in the Expand Virtual Volumes
window, the operation was rejected.
window. See the conditions for increasing THP
V-VOL capacity in
.
Troubleshooting provisioning while using RAID Manager
165