36 chap bidirectional and single settings – HP EVA Array iSCSI Connectivity Option User Manual
Page 209
i.
Click Add under iSNS Servers.
ii.
Enter the IP address of the iSNS server.
iii.
Click OK.
f.
Click Targets.
g.
Select the appropriate target for login.
h.
Click Log On.
i.
Click Advanced.
j.
Select the CHAP Login Information check box.
k.
Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target Secret
box. For example:
CHAPsecret01
l.
Select the Mutual Authentication check box.
m.
Click OK.
n.
Click OK and the initiator completes normal login.
Enabling bi–directional CHAP during discovery and
single–direction CHAP during normal session
lists the parameters you need to enable single-direction CHAP during discovery and
bidirectional CHAP during normal session.
Table 36 CHAP bidirectional and single settings
mpx100/100b secret settings
MS Initiator secret settings
iSCSI Port
hpstorageworks
General Tab Secret
Hpstorageworks
Discovered iSCSI Initiator CHAPsecret01
Add Target Portal
CHAPsecret01
iSCSI Presented Target
N/A
Log on to Target
CHAPsecret01
NOTE:
The above secret settings are for example only. Please configure CHAP with settings that apply to
your specific network environment.
1.
Enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry. Select one of the following
procedures, depending upon the interface you are using:
a.
To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using HP
StorageWorks mpx Manager:
• If the iSCSI Initiator is not listed under Discovered iSCSI Initiators:
i.
Go to the Wizard menu and select the Add Initiator Wizard and enter the iqn
name string.
ii.
Select the Enable CHAP check box.
iii.
Enter a CHAP secret. For example:
CHAPsecret01
• If the iSCSI Initiator is already listed under Discovered iSCSI Initiators:
i.
Select the Initiator in the left-hand column of the Discovered ISCSI Initiator list.
ii.
Click the Information tab.
iii.
Select the Enable CHAP check box.
iv.
Enter a CHAP secret. For example:
CHAPsecret01
b.
To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the
mpx100/100b CLI:
• If the iSCSI Initiator is not listed under the Show Initiators command:
EVA iSCSI connectivity user guide