Show properties command, Show system command – HP EVA Array iSCSI Connectivity Option User Manual
Page 161

Authority
None
Syntax
show perf
Examples
The following is an example of the show perf command:
mpx100 #> show perf
WARNING: Valid data is only displayed for port(s) that are not
associated with any configured FCIP routes.
Port Bytes/s Bytes/s Bytes/s Bytes/s Bytes/s
Number (init_r) (init_w) (tgt_r) (tgt_w) (total)
—— ——– ——– ——– ——– ——–
GE1
0
0
0
27K
27K
GE2
0
0
0
0
0
FC1
0
0
0
0
0
FC2
0
27K
0
0
27K
Show Properties command
Displays the values of both the Inactivity Timer and the CLI Prompt name.
Authority
None
Syntax
show properties
Examples
The following is an example of the show properties command:
mpx100 #> show properties
CLI Properties
—————-
Inactivty Timer 15 minutes
Prompt String
mpx100
Show System command
Displays the mpx100/100b product information, including serial number, software and hardware
versions, configuration, and temperature.
Authority
None
Syntax
show system
Examples
The following is an example of the show system command:
mpx100 #> show system
System Information
——————–
Product Name
HP StorageWorks mpx100
Symbolic Name
Rack3
System Mode
iSCSI Server Connectivity Mode
Serial Number
0539A01070
HW Version
2
SW Version
1.0.5.0
No. of FC Ports
2
No. of iSCSI Ports
2
Log Level
0
Log Length (KB)
32768
Temperature (c)
32
EVA iSCSI connectivity user guide
161