ID
Log message
Message
Number
Description
102659 #%d: QLInitializeAdapter: Load ISP2322
transmit sequencer code failed
259
FC processor transmit sequencer code
load failed.
102662 #%d: QLInitializeAdapter: Verify
Checksum command failed (%x)
262
FC processor firmware checksum
failed.
102680 #%d: QLInitializeFW: FAILED
280
FC processor firmware initialization
failed.
102688
#%d: QLInterruptServiceRoutine: Risc
pause %x with parity error hccr %x,
Disable adapter
288
FC processor paused due to internal
parity error.
102689 #%d: QLInterruptServiceRoutine: Invalid
interrupt status: %x
289
FC processor returned invalid interrupt
status.
102716
#%d: QLIsrEventHandler: System
error event (%x), MB1=%x, MB2=%x,
MB3=%x, MB4=%x, MB5=%x,
MB6=%x, MB7=%x
316
FC processor system error.
102746 #%d: QLProcessResponseQueue: Invalid
handle %x, type %x
346
Response queue entry contains invalid
handle.
102752
#%d: QLTimer: Ext Ram parity error
exceed limit cnt 0x%x, limit 0x%x,
Disabled adapter
352
FC processor external SRAM parity
error count exceeded limit: FC port
disabled.
102755 #%d: QLTimer: Heartbeat failed
355
FC processor heartbeat failed.
102800 #%d: QLRestartRisc: restart RISC
400
FC processor being restarted.
System
The fatal log messages for system modules are listed and described in
.
Table 31 System—fatal log messages
ID
Log message
Mes-
sage
Number
Description
233473
memory monitor: Detected Uncorrectable
Ecc %08lx system is rebooting in 5
secs\n
1
Uncorrectable memory error detected at
address provided in log message.
233474 Failed to register interrupt handler!\n
2
Attempt to register interrupt handler failed.
233475 %s class_simple_create failed\n
3
Failed class_simple_create system
call from memory monitor initialization
routine.
190