176 Command Line Interface

system

Prompts you in a line-by-line fashion to change system configuration settings.

Table 52

describes

the system configuration fields. For each parameter, enter a new value or press

Enter to accept

the current value shown in brackets.

NOTE:

Changing the IP address will terminate all Ethernet management sessions.

Table 52

System configuration settings

Entry

Description

Eth0NetworkDiscovery

Ethernet boot method: 1 - Static, 2 - Bootp, 3 - DHCP, 4 - RARP. The default
is 1 - Static.

Eth0NetworkAddress

Ethernet Internet Protocol (IP) address. The default is 10.0.0.1.

Eth0NetworkMask

Ethernet subnet mask address. The default is 255.0.0.0.

Eth0GatewayAddress

Ethernet IP address gateway. The default is 10.0.0.254.

AdminTimeout

Amount of time in minutes the switch waits before terminating an idle
Admin session. Zero (0) disables the time out threshold. The default is 30,
the maximum is 1440.

InactivityTimeout

Amount of time in minutes the switch waits before terminating an idle
Telnet CLI session. Zero (0) disables the time out threshold. The default is 0,
the maximum is 1440.

LocalLogEnabled

Enables (True) or disables (False) the saving of log information on the
switch. The default is True.

RemoteLogEnabled

Enables (True) or disables (False) the recording of the switch event log on a
remote host that supports the syslog protocol. The default is False.

RemoteLogHostAddress

The IP address of the host that will receive the switch event log information
if remote logging is enabled. The default is 10.0.0.254.

NTPClientEnabled

Enables (True) or disables (False) the Network Time Protocol (NTP) client
on the switch. This client enables the switch to synchronize its time with an
NTP server. This feature supports NTP version 4 and is compatible with
version 3. An Ethernet connection to the server is required and you must
first set an initial time and date on the switch. The synchronized time
becomes effective immediately. The default is False.

NTPServerAddress

The IP address of the NTP server from which the NTP client acquires the
time and date. The default is 10.0.0.254.

EmbeddedGUIEnabled

Enables (True) or disables (False) the McDATA Web Server and McDATA
Element Manager. Changing this parameter to False while the application
is running will terminate the application. The default is True.