display [filter]
Specifies the log events to automatically display on the screen according to the event severity
levels given by [filter]. [filter] can be one of the following values:
Critical
Critical severity level events. The critical level describes events that are generally disruptive to
the administration or operation of the fabric, but require no action.
Warn
Warning severity level events. The warning level describes events that are generally not
disruptive to the administration or operation of the fabric, but are more important than the
informative level events.
Info
Informative severity level events. The informative level describes routine events associated with
a normal fabric.
None
Specifies no severity levels for display on the screen
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events for the
specified components or ports. [filter] can be one of the following values:
Critical
Monitors critical events. The critical level describes events that are generally disruptive to the
administration or operation of the fabric, but require no action.
Warn
Monitors warning and critical events. The warning level describes events that are generally
not disruptive to the administration or operation of the fabric, but are more important than the
informative level events.
Info
Monitors informative, warning, and critical events. The informative level describes routine
events associated with a normal fabric. This is the default severity level.
None
Monitors none of the severity levels
port [port_list]
Specifies one or more ports to monitor for events. Choose one of the following values:
[port_list]
Specifies port or ports to monitor. Use a
numbered beginning with 0.
All
Specifies all ports
None
Disables monitoring on all ports
restore
Restores and saves the port, component, and level settings to the default values
save
Saves the log settings for the component, severity level, port, and display level. These settings
remain in effect after a switch reset. The log settings can be viewed using the
Show Log Settings
command. To export log entries to a file, use the Set Log Archive
command.
start
Starts the logging of events based on the Port, Component, and Level operands assigned to the
current configuration. The logging continues until you enter the Set Log Stop command.
stop
Stops logging of events