162 Command Line Interface

threshold

Initiates a configuration session by which to generate and log alarms for selected events. The
system displays each event, its triggers, and sampling window one line at a time and prompts
you for a value. For each parameter, enter a new value or press

Enter to accept the current value

shown in brackets. These parameters must be saved in a configuration and activated before they
will take effect. See the Config command

for information about saving and activating a

configuration.

Table 47

describes the Set Config Threshold parameters. The switch will down a

port if an alarm condition is not cleared within three consecutive sampling windows (by default
30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold
monitoring detects that the error rate has fallen below the falling trigger.

Table 47

Set Config threshold parameters

Parameter

Description

Threshold Monitoring Enabled

Master enable/disable parameter for all events. Enables (True)
or disables (False) the generation of all enabled event alarms.
The default is False.

CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled

The event type enable/disable parameter. Enables (True) or
disables (False) the generation of alarms for each of the
following events:

CRC errors

Decode errors

ISL connection count

Device login errors

Device logout errors

Loss-of-signal errors

Rising Trigger

The event count above which a rising trigger alarm is logged.
The switch will not generate another rising trigger alarm for
that event until the count descends below the falling trigger
and again exceeds the rising trigger.

Falling Trigger

The event count below which a falling trigger alarm is logged.
The switch will not generate another falling trigger alarm for
that event until the count exceeds the rising trigger and
descends again below the falling trigger.

Sample Window

The period of time in seconds in which to count events