Set log command – HP M-series HA-Fabric Manager Software User Manual
Page 168
168 Command Line Interface
Set Log command
Description Specifies the events to record in the event log and display on the screen. You determine what events
to record in the switch event log using the Component, Level, and Port operands. You determine what
events are automatically displayed on the screen using the Display operand. Alarms are always
displayed on the screen.
Authority Admin session
Syntax
set log
archive
clear
component [filter_list]
display [filter]
level [filter]
port [port_list]
restore
save
start (default)
stop
Operands
archive
Collects all log entries and stores the result in a new file named logfile that is maintained in
switch memory where it can be downloaded using FTP. To download logfile, open an FTP
session, log in with account name (“images”) and password (“images”), and enter “get logfile”.
clear
Clears all log entries.
component [filter_list]
Specifies one or more components given by [filter_list] to monitor for events. A component is a
firmware that is responsible for a particular portion of switch operation. Use a
delimit values in the list. [filter_list] can be one or more of the following:
All
Monitors all components. To maintain optimal switch performance, do not use this setting with
the Level operand set to Info.
Chassis
Monitors chassis hardware components such as fans and power supplies
Eport
Monitors all E_Ports
Mgmtserver
Monitors management server status
Nameserver
Monitors name server status
None
Monitor none of the component events
Other
Monitors other miscellaneous events
Port
Monitors all port events
SNMP
Monitors all SNMP events
Switch
Monitors switch management events
Zoning
Monitors zoning conflict events