7 Troubleshooting

Problem

Check the following

The power does not turn on.

• Check whether the AC Adaptor is connected correctly.

The Web setup tool does not

display.

• Check whether the LAN connector is connected correctly.

• Check the setup for the IP address on this product.

• Check the setup for the IP address on the PC side.

• Refer to 2.5 "Network Setup" for the IP address set up procedure.

The Web setup tool does not

display correctly.

• Make sure the browser information has been recently updated.

The Signal Tower does not turn

on.

• Check whether the AC Adaptor is connected correctly.

• Check the setup of the Signal Tower operation with the Web setup tool.

Refer to "4.13 Normal Mode Setting Screen" for the procedure to set up for the

normal operation mode.

• After any recombination of tiers to the Signal Tower has been done, check whether

the Signal Tower lights up by accessing the Signal-Tower Output Control screen. If

the light does not turn on, it may not be installed correctly.

Refer to "4.15 Signal-Tower Output Control Screen" for the procedure to control

the Signal-Tower output.

The buzzer does not sound.

• Check whether the volume switch has been set in the "OFF" position.

• After each setup, check the buzzer operation.

Refer to "4.15 Signal-Tower Output Control Screen" for the procedure to setup the

buzzer output.

Socket communication does not

work.

• Check whether the correct communication port has been set.

Refer to "4.5 Socket Communication Configuration Screen" for the setup procedure

of the Socket Communication.

• Check whether the data had been sent correctly.

For data transmitted by the Socket Communication, refer to "3.5 PHN Command

Reception Function" and "3.6 PNS Command Reception Function".

The RSH command data is

unreceivable.

• Check the command reception setup.

Refer to "4.8 Command Reception Configuration Screen" for the setup procedure

of the command reception.

• Check whether the security settings for the PC has granted permission.

I want to return it to the factory

settings.,

• Refer to "3.13 Reinitialization".

The E-mail transmission cannot

be sent.

• Check whether the setup for the server is correct.

The SNMP SET/GET does not

work.

• Check the SET Community name and GET Community name.

The status LED is flashing.

• It may be in the factory-shipment inspection mode. Please reboot this product.