PATLITE NHL User Manual
Page 63
63
4
Table 4.11.1 Application Monitor Setup Parameters
Item
Contents
Default
Value
Input
Parameter
Setting
Option
Monitoring Target
Address
Setup the IP address for transmission monitoring.
Blank
IP Address Format
O
Reception Port
Number
Set up the reception port used for the application
monitoring.
0
Half-width numbers 9000-
9999 (When the address
column for the monitor is
blank, it is 0)
―
Equipment
Name
Setup the name for the Ping transmission monitoring.
Blank
Full/Half-width Characters
Maximum 31 Characters
O
Monitoring
Duration
Setup the duration for monitoring the application
software.
0
Half-width alphanumeric
1 through 60000(sec)
O
Red
Select from: OFF- ON- Lighting- Flashing1- Flashing2-
No Flashing- No Change
No Change
―
―
Amber
Select from: OFF- ON- Lighting- Flashing1- Flashing2-
No Flashing- No Change
No Change
―
―
Green
Select from: OFF- ON- Lighting- Flashing1- Flashing2-
No Flashing- No Change
No Change
―
―
Blue
Select from: OFF- ON- Lighting- Flashing1- Flashing2-
No Flashing- No Change
No Change
―
―
White
Select from: OFF- ON- Lighting- Flashing1- Flashing2-
No Flashing- No Change
No Change
―
―
Buzzer
Select from:
Pattern1- Pattern2- Pattern3- Pattern4- Stop- No Change No Change
―
―
Transmission Select the Active/Inactive condition for the E-mail Sending.
Inactive
―
―
Subject
Select the E-mail subject title
1. Message
―
―
Message
Select the E-mail message to text
1:
―
―
TRAP
Transmission
Select the Active/Inactive condition for the trap
transmission.
Inactive
―
―