PATLITE NHL User Manual
Page 76
5
76
OID
Name
Model
MAX-ACCESS
Comment
1
ident
ID Group
1.1.0
identSWinitVersion
String(2)
read-only
OS Version
1.2.0
identSWAgentVersion
String(3)
read-only
Application Version
1.3.0
idensHWVersion
String(3)
read-only
Hardware Version
4
monitor
Monitor Group
4.1
pingServer
ping monitoring setting
4.1.1.0
pingServerNumEntries
INTEGER
read-only
Ping monitoring count
4.1.2.0
pingServerTable
not-accessible ping monitoring table
4.1.2.1.0
pingServerTableEntry
not-accessible
4.1.2.1.1.(index) pingServerTableIndex
INTEGER
read-only
ping monitoring index
4.1.2.1.2.(index) pingServerName
STRING(31)
read-only
ping monitor name
4.1.2.1.3.(index) pingServerAlertValue
INTEGER{ normal(1),
occurred(2) }
read-only
ping monitor condition
normal(1), event occurred(2)
4.1.2.1.4.(index) pingServerIpAddress
STRING(63)
read-only
ping monitoring address
4.3
logDump
log setting
4.3.1.0
logDumpEventlog1
OBJECT IDENTFIER
read-only
event log from 1 to 85
4.3.2.0
logDumpEventlog2
OBJECT IDENTFIER
read-only
event log from 86 to 170
4.3.3.0
logDumpEventlog3
OBJECT IDENTFIER
read-only
event log from 171 to 255
5.1
controlLight
signal tower control
5.1.1.0
controlLightNumEntries
INTEGER
read-only
count of control entries
5.1.2.0
controlLightTable
not-accessible signal tower table
5.1.2.1.0
controlLightTableEntry
not-accessible
5.1.2.1.1.(index) controlLightDeviceColor
INTEGER {red(1), am-
ber(2), green(3), blue(4),
clear(5), buzzer(6) }
read-only
signal tower color
R(1)/Y(2)/G(3)/B(4)/C(5)/Buz(6)
5.1.2.1.2.(index) controlLightControlState
INTEGER {turn-off(1),
turn-ON(2), blinking-pat-
-pat-
tern(3), nop(4), blinking-
patern2(5), sound-
pattern4(6) }
read-write
Signal Tower Status: lights and buzzer
off(1)/lighting and buzzer synchronized
with light pattern1(2)/flashing pattern1
and buzzer synchronized with light
pattern2(3)/no change(4)/flashing pat-
tern2 and buzzer synchronized with light
pattern3(5)/buzzer synchronized with light
pattern 4(6). controlLightControlTimer is
set by entering values above zero.
5.1.2.1.3.(index) controlLightControlTimer
INTEGER(-1,99)
read-write
A preset value is decremented for every
second until it is 0, then it changes to the
status designated by the controlLightCon-
trolState.
5.1.2.1.4.(index) controlLightCurrentState
INTEGER { off(1), on(2),
blinking-pattern1(3),
blinking-pattern2(4),
sound-pattern4(5) }
read-only
The present status is displayed.
lights and buzzer off(1)/lighting and buzzer
synchronized with light pattern1(2)/flash-
ing pattern1 and buzzer synchronized
with light pattern2(3)/flashing pattern2 and
buzzer synchronized with light pattern3(4)/
buzzer synchronized with light pattern4(5)
5.1.3.0
controlLightSnmpClear
INTEGER{ execute(1),
nop(0) }
read-write
execute(1) setup will clear the Signal
Tower operation.
6
Trap
6.1
trapPatliteAlarmAdded
OBJECT-IDENTIFIER
not-accessible When an abnormality in the PING occurs
6.2
trapPatliteAlarmRemoved
OBJECT-IDENTIFIER
not-accessible When an abnormality in the PING is
restored
6.3
trapPatliteTrapReceived
OBJECT-IDENTIFIER
not-accessible When a trap is received
6.4
trapPatliteClearExecuted
OBJECT-IDENTIFIER
not-accessible When the clear button is pushed
6.5
trapPatliteRshExecuted
OBJECT-IDENTIFIER
not-accessible When an RSH command is executed
6.6
trapPatliteAppMonitorAlarmAdded
OBJECT-IDENTIFIER
not-accessible When an abnormality in the application
occurs
6.7
trapPatliteAppMonitorAlarmRemoved OBJECT-IDENTIFIER
not-accessible When an abnormality in the application is
restored
6.8
trapPatliteTestSwExecuted
OBJECT-IDENTIFI-
ER
not-accessi-
ble
When the test switch is pushed
Table 6.2.1 MIB Specifications