beautypg.com

PATLITE PHC-100A User Manual

㧵㧺㧿㨀㧾㨁㧯㨀㧵㧻㧺 㧹㧭㧺㨁㧭㧸, Pc-output relay unit

background image

٨
٨

٨

Please be careful to wire the unit according to the following instructions. Mis-wiring will damage the internal circuitry and could cause a fire.
This product is for indoor use only. It should be used in a place where it is protected from rain and water. Moisture in the unit could cause a
breakdown of the unit or electric shock.

Warning

Do not use this product in a corrosive gas atmoshere.

Caution

8077-F

'09.4,AUTO

8077-F

T95100062

FT003

TO OPERATE THIS PRODUCT SAFELY, PLEASE OBSERVE THE FOLLOWING

㧵㧺㧿㨀㧾㨁㧯㨀㧵㧻㧺 㧹㧭㧺㨁㧭㧸

[ TYPE : PHC-100A

Thank you for purchasing the PC-

Output Relay Unit,PHC-100A

. To ensure proper operation, prease read

this instruction manual thoroughly before attempting to use the system. Also, when undertaking maintenance,
inspection or repair work, be sure to refer to this manual. If you have any questions regarding this product,
please feel free to contact us.

PC-Output Relay Unit

1.Parts name

5.Specifications

Model

PHC-100A

Rated voltage

24V DC

Operative voltage range

108V AC

㨪132V AC (AC adaptor (bundled))

Power consumption

Approx. 4W

Operative temp. range

0

͠㨪 40͠

Operative humidity range

85

㧑RH

Dielectric strength

Insulation resistance

To be measured by an insulation measuring device of 500VDC between the power terminal and the case. More than 1M

ǡ

1000VAC being applied between the power terminal and the case for 1 minute. Not braking insulation

Anti-noise

1500Vp-p

ޓPals range 1Ǵsecޔ100nsec

Vibration proof

19.6m/s

2

Mass

Unit: Approx. 300 g Supplied AC adaptor: approx. 160g

Serial communication

Serial interface: RS-232C compliant

Transmission mode

㧦Half-duplex mode

, Transmission code

㧦ASCII code

Synchronous mode

㧦synchronous mode

, Communication speed

㧦9600bps

Data length

㧦8 bit

, Stop bit

㧦1 bit

Parity, Flow Control: no setting required

Connector

D-SUB9P

ޓMale connectorޓ

٨

٨

PATLITE Corporation disclaims all liability for any malfunction or damage occurring as a result of handling contrary to the instructions,
cautions and warnings mentioned in this manual.
Specifications are subject to change without notice.

Caution

Reset switch

Intemal contact

Output terminal

Momentary switch with green power monitor LED
On : All switch outputs are turned off
: All the communication command is invalid.
Off : Usual operation. CTS line of RS-232C is on and switch LED is on.

(1800

)

60

41

44

Jack

O.D.

㧦Ǿ5.5

I.D.

㧦Ǿ2.1

ធὐኈ㊂ ޓޓޓޓޓޓޓ߹ߢ

Contact capacity

125V AC,3A
30V DC,3A

8

7

6

5

4

3

2

1

࡝࡟࡯ធὐNo.(Relay contact No.)

㔚✢ⵍⷒ೸߈㐳ߐ㧦9mm(Strip)

න✢:Ǿ0.4㨪1.2mm(Single wire)
᠐✢:0.3㨪0.75mm

2

(Twist wire)

MODEL

PHC-100A

Reset switch

RS-232C

Power

24V DC

૶ ↪ น ⢻ 㔚 ✢
A p p l i c a b l e w i r e

11

5

1

1

7.5

100

Connect-disconnect lever

Wire insert point

AC adaptor connection

RS-232C port(D-SUB9 pin)

Output terminal block

̪Lot number indicated

Reset switch with green power monitor LED

31

35

#4-40UNC Inch screw

٨
٨
ޓ
٨

Be sure to turn the power off before wiring. You may short-circuit the PCB or experience an electric shock.
Since this product uses screwless terminals, be sure to follow the instructions in this manual regarding wire type, wire diameter, and strip
length. Otherwise, there may be bad connections, excessive heating, or wires coming out of the terminals.
Make sure to insert the wire all the way to the bottom of the receptacle so that none of the stripped section is showing.
Otherwise there may be faulty operation, leakage or fire if the stripped section touches the product or if the wire comes out.

Warning

2.How to make wiring connection

٨

ޓ
٨

The capacity of the internal contact is AC125V(DC30V), 3A. When inductive loads such as bulbs or motors are used, there is an
increase in current, which may shorten the life of the internal contact.
If the load current exceeds the capacity, or there is excessive inrush current, it may cause burning or welding of the contact.
This product is to be connected to one RS-232C serial port. Do not connect other devices simultaneously.
Otherwise, the result may be malfunction or damage to the serial port or devices.

4.Before requesting service

Substance

AC adaptor (bundled)

Caution

Please check the list shown below before requesting repairs. If the product still does not work, please contact us for repairs.
Please feel free to contact our sales office with any questions concerning the product.
For inquiry, you are required to identify the number indicated on the name plate of the product.

Power lamp stays
turned off

No reply (ACK, NACK)

࡮Confirm if supplied adaptor is securely inserted to a wall socket.
࡮Confirm if an adapter jack is securely inserted to the main body.

࡮Confirm if straight cable is used
࡮Confirm a communication condition and protocol
࡮Set ID to ??"[3FH, 3FH]
࡮Confirm an end code "!"[21H]
࡮Confirm if the reset switch is not being pressed

Problems

What to do

Please note that any malfunction or damage resulting from modification is not guranteed under the warranty.

̪

NOTES TO BE OBSERVED FOR SAFE OPERATION

عThe indications for warning are divided into the following classes according to the degree of danger or damage incurred when the warning is not taken
into consideration and the product is not corrently used.

Note to be followed to prevent any damage to the user and other personnel or to assets are as follows:

This symbol marks important instructions that, if ignored or incorrectly followed, could conceivably lead to death or serious injury.

This symbol marks important instructions that, if ignored or incorrectly followed, could conceivably lead to injury or property damage.

Caution

Warning

Terminal : Screwless terminal, Number of terminals: 16,
Applicable wire: Solid wire

Ǿ0.4㨪Ǿ1.2mm (AWG26㨪AWG18)

ޓޓޓޓޓޓ 㧦 Stranded wire Ǿ0.3㨪Ǿ0.75mmޓ(AWG22㨪㧭㨃㧳20)

̪In case of using stranded wire, make sure to use an element wire which has more than Ǿ0.18mm diameter.

Contact:Non Voltage contact, Number of contacts:8, Contact Capacity: AC125V,3A/DC30V,3A
Life: Min. 200,000 operating (Rated Load, Operating 1,800times/h)

2

㧙㧝㧙

㧙㧠㧙