4

Table 4.8.1 RSH Command Setup Parameters

Item

Contents

Default

Value

Input Parameter

Setting

Option

RSH Server

Function

Select Active/Inactive for the RSH server

function.

Active

RSH Alert Timer

Reset Function

Select “Shared” or “Separate” to control

the Signal Tower lights and buzzer

E-mail

Transmission

Select Active/Inactive for sending an E-

mail when a command is received.

Inactive

Subject

Select the subject title for the mail to be

transmitted.

1. Message

Message

Select the message text for the mail to be

transmitted.

1:

E-mail

Receiver

Select the recipient to send E-mail to.

Undefined

TRAP

Transmission

Select Active/Inactive for the TRAP

transmission when an RSH Command is

received.

Inactive

Designated

Sender Address

Setup a designated address for a sender

when an RSH Command is recieved.

Active

Invalid Designated

Sender Address/

Common Login Name

IP Address

When the designated sender address

setup is not active, up to 16 accounts can

be used to notify senders when an RSH

Command is received.

Blank

IP Address Format

O

Sender IP Address The designated IP address used when a

command is executed.

Blank

Half-width alphanumeric char-

acter, period “.”, hyphen “-”

Maximum 16 Characters

O

Login Name

The login name used is entered to allow

command execution.

Blank

Half-width alphanumeric char-

acter, period “.”, hyphen “-”

Maximum 16 Characters

O