3
Response from this product
Normal response (output response)
ACK
06H
Response Error (output failed)
NAK
15H
Reading Command
Transmitting the following data will execute the status of the Signal Tower and buzzer.
Product
Classification
"XX”
Identifier
"G"
(Empty) Data Size
58H
58H
47H
00H
00H
00H
Response from the Read Command
Data Control Bits 6 bit
Refer to "Capacity of Data Control Bits"
[Example for a data acquisition response]
Signal Tower “Red: Flashing Pattern1, Amber: Flashing Pattern2, Green: Lighting with no buzzer” is
read, and the response from this product is indicated in the following table after the command trans-
mission.
Data Control Bits 6 bit
Red Amber Green Blue White Buzzer
02H
03H
01H
00H
00H
00H
Status Condition "Clear" Command
The change in the operating state for this product is made when setting up the "Normal Mode Setup".
Product
Classification
"XX”
Identifier
"C"
(Empty) Data Size
58H
58H
43H
00H
00H
00H