Yokogawa Button Operated MV2000 User Manual
Page 294
App-11
M-4660
Appendix
1
2
3
4
5
6
7
8
9
10
11
12
13
App
Index
File Output Example
Below is an example of manually sampled data for channels 1, 2, 3, and 4.
YREC
Manual Sample Data
Version 1.00.00
Model
RD-MV2000
Language Code
shift-JIS
File Status
Progress
Serial No.
S5E701600
File Header
Ch
CH001
CH002
CH003
CH004
Tag
TI-101
OUT-102
FI-103
VA-204
Unit
˚C
V
m3/h
%
2008/01/23 08:57:22 213.8
0.517
368.4
68.9
2008/01/23 08:57:28 208.6
0.494
363.0
68.1
Note
• The output when error data, range-out data, or computation range-out data is detected
Channel
Data
Output
Measurement
channels and
Error
(Space)
external input
channels
Positive range-out (includes burnout detection)
99999
Negative range-out (includes burnout detection)
–99999
Computation
channels
Error
999999999
Positive computation range-out (when the value
exceeds approx. 3.4E+38)
999999999
Negative computation range-out (when the value is
less than approx. –3.4E+38)
–999999999
• The MV generates a new manually sampled data file in the following cases:
• A measurement channel is changed to Skip from a range other than Skip.
• A measurement channel is changed from Skip to a range other than Skip.
• A computation or external input channel is changed from On to Off or Off to On.
• The unit is changed.