beautypg.com

Transporting and storage conditions, Compliant standards – Yokogawa Button Operated MV2000 User Manual

Page 278

background image

13-16

M-4660

Transporting and Storage Conditions

Item

Specifications

Ambient temperature

–25 to 60°C

Ambient humidity

5 to 95%RH (no condensation)

Vibration

10 to 60 Hz, 4.9 m/s

2

or less

Shock

392m/s

2

or less (in packaged condition)

Compliant Standards

Item

Specifications

CSA

CSA22.2 No.61010-1, installation category II,

1

pollution degree 2,

2

and measurement category II

UL

UL61010-1 (CSA NRTL/C)

CE

EMC directive

EN61326 compliant (Emission: Class A, Immunity: Annex A)
EN61000-3-2 compliant
EN61000-3-3 compliant
EN55011

Low voltage directive

EN61010-1, installation category II, measurement category II,

3

pollution degree 2

C-Tick

AS/NZS CISPR11 compliant, Class A Group 1

1 Installation category (overvoltage category) II: Describes a number which defines a transient overvoltage condition. Implies

the regulation for impulse withstand voltage. “II” applies to electrical equipment which is supplied from the fixed installation
like a distribution board.

2 Pollution degree 2: Describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength or surface

resistivity is adhering. “2” applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs.

3 Measurement category II: Applies to measuring circuits connected to low voltage installation, and electrical instruments

supplied with power from fixed equipment such as electric switchboards.

13.6 General Specifications

This manual is related to the following products: