5 initializing the mv – Yokogawa Button Operated MV2000 User Manual
Page 209
9-7
M-4660
Environment Settings
1
2
3
4
5
6
7
8
9
10
11
12
13
App
Index
9.5
Initializing the MV
This section explains how to initialize the MV and how to clear the internal memory.
For a list of default settings, see the First Step Guide (IM RD-MV1000-02E/IM RD-
MV2000-02E).
Display
Press MENU and then select Menu tab > Basic setting mode > Initialize tab > Clear
settings and data or Clear data only.
Settings
• Initialization Method
Menu Item
Description
Clear settings and
data
Initializes the settings in Basic Setting Mode and Setting Mode to their
default values and clears the data in the internal memory.
Clear data only
Clears the data in the internal memory.
Data in the Internal Memory That Is Cleared
Display data, event data, manually sampled data, report data (/M1 and /PM1 options),
and log information.
Procedure
1.
Select Clear settings and data or Clear data only.
2.
Press DISP/ENTER.
A confirmation window opens.
3.
Select Yes, and then press DISP/ENTER.
The specified operation is executed, and the MV returns to Operation Mode.
If you do not want to initialize, select No, and press DISP/ENTER.