Setup menus, Factory menus, Introduction – Watlow Series 998 User Manual
Page 7
Introduction
WATLOW Series 998 User’s Manual
iii
Introduction
From the Setup menus, press both the Up-arrow and Down-arrow keys
>
and
<
for three seconds to reach the Factory menus.
To return to the Display Loop from any point in any menu, press the Display key
∂
.
[OtPt]
[`SEt]
[Ot1A]
[HY1A]
[Ot2A]
[HY2A]
[PrcA]
[Ot1b]
[HY1b]
[Ot2b]
[HY2b]
[Prcb]
[`Ot3]
[`Al3]
[HYS3]
[LAt3]
[SIL3]
[`Ot4]
[`AL4]
[HYS4]
[LAt4]
[SIL4]
[Aout]
[Prc3]
[`ArL]
[`ArH]
[ACAL]
[InPt]
[`SEt]
[`In1]
[dEC1]
[`rL1]
[`rH1]
[CAL1]
[rtd1]
[Ftr1]
[`In2]
[dEC2]
[`rL2]
[`rH2]
[CAL2]
[rtd2]
[Ftr2]
[Lin2]
[`Alt]
[gLbl]
[`Set]
[`C_F]
[FAIL]
[`err]
[`Ei1]
[Anun]
[AtSP]
[rP`A]
[rt`A]
[rP`b]
[rt`b]
Output Menu
Setup Menus
Output 1A
Hysteresis 1A
Output 2A
Hysteresis 2A
Process A
Output 1B
Hysteresis 1B
Output 2B
Hysteresis 2B
Process B
Output 3
Alarm 3
Hysteresis 3
Latching 3
Silencing 3
Output 4
Alarm 4
Hysteresis 4
Latching 4
Silencing 4
Analog Output
Process 3
Retransmit Low Limit
Retransmit High Limit
Retransmit Calibration Offset
Input Menu
Setup Menus
Input 1
Decimal 1
Range Low 1
Range High 1
Calibration Offset 1
RTD Calibration Curve 1
Input 1 Software Filter
Input 2
Decimal 2
Range Low 2
Range High 2
Calibration Offset 2
RTD Calibration Curve 2
Input 2 Software Filter
Input 2 Linearization
Altitude
Global Menu
Setup Menus
Celsius-Fahrenheit
Failure Mode
Error Latching
Event Input 1
Annunciator
Auto-tune Set Point
Ramping Channel A
Ramp Rate Channel A
Ramping Channel B
Ramp Rate Channel B
[COM]
[`SEt]
[bAUd]
[dAtA]
[Prot]
[Addr]
[IntF]
Communications Menu
Setup Menus
Baud Rate
Data Bits and Parity
Protocol Type
Address
Interface Type
Setup Menus
>
>
>
>
µ
µ
µ
µ
[diAg]
[Fcty
[dAtE]
[SOFt]
[Sn--]
[AMb]
[`gnd]
[`rEF]
[cnt1]
[cnt2]
[itY1]
[ity2]
[OtY1]
[OtY2]
[OtY3]
[OtY4]
[dISP]
[tout]
[PLOC]
[Fcty]
[`LOC]
[`SYS]
[PidA]
[Pidb]
[InPt]
[OtPt]
[gLbL]
[COM]
[diAg]
[`CAL]
[`CAL]
[Fcty]
[A`50]
[A`00]
[``tc]
[a`OH]
[A`20]
[A`15]
[A380]
[A10U]
[A`OU]
[A20A]
[A`4A]
[A`Ou]
[A100]
[b`50]
[b`00]
[b`OH]
[b`20]
[b`15]
Diagnostics Menu
Factory Menus
Factory Ship Date
Software Revision
Serial Number
Ambient Temperature
Ground A/D Count
Ambient A/D Count
Input 1 A/D Count
Input 2 A/D Count
Input 1 Module
Input 2 Module
Output 1 Module
Output 2 Module
Output 3 Module
Output 4 Module
Test Displays
Test Outputs
Panel Lockout Menu
Factory Menus
User Lockout
System Menu Lockout
PID A Menu Lockout
PID B Menu Lockout
Input Menu Lockout
Output Menu Lockout
Global Menu Lockout
Communications Menu Lockout
Diagnostics Menu Lockout
Calibration Menu Lockout
[b380]
[b10U]
[b`OU]
[b`4A]
[b`Ou]
[b100]
[1`4`]
[1`20]
[1`10]
[110`]
[2`4`]
[2`20]
[2`0`]
[2`10]
[3`LO]
[3`HI]
[`rSt]
[`dFL]
Calibration Menu
Factory Menus
Restore Factory Values
Default Prompts
>
>
>
Factory Menus
µ
µ
µ
µ