7.
ASEL, PSEL, SSEL

85

(2) Positioner mode

Regardless of the settings of I/O parameter Nos. 1, 16 and 17, physical ports are assigned from No. 0 for input
ports and from No. 300 for output ports.
As shown in the I/O port table on the next page

and subsequent pages, input ports of Nos. 0 to 23 and output

ports of Nos. 300 to 307 are used.
In this case, both I/O parameter Nos. 14 and 15 are set to 24.

(Note) Set the same number of points for I/O parameter Nos. 14 and 15 according to the number of input or

output ports, whichever is greater.