4. XSEL-R/S/RX/SX/RXD/SXD

53

No.

Error name

Contents and Treatment

D77

Fieldbus error (Exception)

A communication board error was detected.
Reboot the XSEL controller. If the same error occurs again, please
contact us.

E1F

I/O Assignment Parameter Error

It is a parameter setting error.
Check to see that a number out of the I/O port number (except for
-1) is not set to I/O Parameters No. 2 to 9, a number out of indication
is not input to I/O port start number, or a number out of indication is
not input to I/O Parameters No. 14 to 17. [Refer to XSEL Controller
Instruction Manual.]

E20

I/O Duplication Assignment Error

I/O assignment is duplicated.
Check to see that a number out of the I/O port number (except for
-1) is not set to I/O Parameters No. 2 to 9, a number out of indication
is not input to I/O port start number, or a number out of indication is
not input to I/O Parameters No. 14 to 17. [Refer to XSEL Controller
Instruction Manual.]
Check the number of the ports that I/O boards are mounted.

E21

,2$VVLJQPHQW1XPEHU2YHUÀRZ(UURU

,2DVVLJQPHQWKDVH[FHHGHGWKHVSHFL¿HGUDQJH
Check to see that a number out of the I/O port number (except for
-1) is not set to I/O Parameters No. 2 to 9, a number out of indication
is not input to I/O port start number, or a number out of indication is
not input to I/O Parameters No. 14 to 17. [Refer to XSEL Controller
Instruction Manual.]
Check the number of the ports that I/O boards are mounted.

E8F

Fieldbus logic error

It is a logic error at the Fieldbus initializing.