IAI America E-Con User Manual
Page 37
3. X-SEL-J/K/P/Q/JX/KX/PX/QX
29
I/O Parameters of X-SEL P/PX/Q/QX Type Controllers
No. Parameter
name
Default
(reference)
Input
range
Setting
Remarks
1
Input/output port assignment type
0
0 ~ 20
1
0: Fixed assignment
1: Automatic assignment (Priorities:
Network I/F module
o Slot 1
(standard I/O) ~)
* Ports are assigned automatically only
for the contiguous slots in use, starting
from slot 1 = For safety reasons.
2
Standard I/O fixed assignment:
Initial input port number (I/O1)
-1
-1 ~ 599
256
0 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
3
Standard I/O fixed assignment:
Initial output port number (I/O1)
-1
-1 ~ 599
556
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
4
Expansion I/O1 fixed assignment:
Initial input port number (I/O2)
-1
-1 ~ 599
-1
0 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
(Slot next to standard I/O)
5
Expansion I/O1 fixed assignment:
Initial output port number (I/O2)
-1
-1 ~ 599
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
6
Expansion I/O2 fixed assignment:
Initial input port number (I/O3)
-1
-1 ~ 599
-1
0 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
7
Expansion I/O2 fixed assignment:
Initial output port number (I/O3)
-1
-1 ~ 599
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
8
Expansion I/O3 fixed assignment:
Initial input port number (I/O4)
-1
-1 ~ 599
-1
0 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
9
Expansion I/O3 fixed assignment:
Initial output port number (I/O4)
-1
-1 ~ 599
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
10 Standard I/O error monitor
0
0 ~ 5
1
0: Not monitored
11 Expansion I/O1 error monitor
0
0 ~ 5
0
1: Monitored
12
Expansion I/O2 error monitor
0
0 ~ 5
0
2: Monitored (24-V I/O power errors
are not monitored)
13
Expansion I/O3 error monitor
0
0 ~ 5
0
3: Monitored (only 24-V I/O power
errors are not monitored).
14
Network I/F card remote input
ports used
64
0 ~ 256
256
Multiple of 16
15
Network I/F card remote output
ports used
64
0 ~ 256
256
Multiple of 16
16
Network I/F module fixed
assignment: Initial input port
number
0 -1
~
599
0
0 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
17
Network I/F module fixed
assignment: Initial input port
number
300 -1
~
599
300
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
18
Network I/F module: Error monitor
1
0 ~ 5
1
0: Not
monitored
1: Monitored
*
Some exceptions apply.
(I/O1) to (I/O4) indicate slot numbers.