23

No.

Parameter name

Input range

Settings

Remarks

1

Input/output port assignment type

0 ~ 20

1

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 ~)
* Ports are assigned automatically only for the

contiguous slots in use, starting from slot 1 =
For safety reasons.

2

Standard I/O fixed assignment:
Initial input port number (I/O1)

-1 ~ 599

000

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

3

Standard I/O fixed assignment:
Initial output port number (I/O1)

-1 ~ 599

300

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

4

Expansion I/O1 fixed assignment:
Initial input port number (I/O2)

-1 ~ 599

256

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

(Slot next to standard I/O)

5

Expansion I/O1 fixed assignment:
Initial output port number (I/O2)

-1 ~ 599

556

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

6

Expansion I/O2 fixed assignment:
Initial input port number (I/O3)

-1 ~ 599

-1

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

7

Expansion I/O2 fixed assignment:
Initial output port number (I/O3)

-1 ~ 599

-1

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

8

Expansion I/O3 fixed assignment:
Initial input port number (I/O4)

-1 ~ 599

-1

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

9

Expansion I/O3 fixed assignment:
Initial output port number (I/O4)

-1 ~ 599

-1

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

10 Standard I/O error monitor

0 ~ 5

2

0: Not monitored

11 Expansion I/O1 error monitor

0 ~ 5

1

1: Monitored

12

Expansion I/O2 error monitor

0 ~ 5

0

2: Monitored (only 24-V I/O power errors are

not monitored)

13

Expansion I/O3 error monitor

0 ~ 5

0

3: Monitored (only 24-V I/O power errors are

not monitored).

(Main application version 0.55 or later)

14

Network I/F card remote input
ports used

0 ~ 256

256

Multiple of 16

15

Network I/F card remote output
ports used

0 ~ 256

256

Multiple of 16

This manual is related to the following products: