7

DEOHWRS5RERW77

56

4.2.2 ProfiBus-DP Communication Connector

The board-end connector is a D-sub 9-pin (female) connector recommended under the ProfiBus-DP standard
EN50170.
The network connector on the other end is not supplied.

Pin No.

Signal name

Explanation

1 NC

Not

connected

2 NC

Not

connected

3

B-Line

Communication line B (positive side)

4 NC

Not

connected

5

GND Signal

ground

6

+5V +5-V

output

7 NC

Not

connected

8

A-Line

Communication line A (negative side)

9 NC

Not

connected

Housing Shield

Cable

shield

* 1, 2, 4, 6, 7 and 9 are not used. (These signals need not be wired.)

4.2.3 Termination switch (Bus termination settings)

Among the units connected to a ProfiBus-DP network, the devices at both ends require termination to prevent
reflected waves from entering the bus line again.
This ProfiBus-DP module provides a termination switch that makes this termination easy.

The user need not install a separate terminal resistor. Never install an additional terminal resistor, as it may
have negative impact on bus communication or cause a communication error, etc.

.

Termination switch ON

Termination enabled
(If this switch is turned ON mistakenly when the module is connected in a position
other than the end of the network, bus communication may be negatively impacted
or a communication error, etc., may result.)

Termination switch OFF

Termination disabled

5.2.2