(2) Factory-set parameters for the TT type

No. Parameter

name

Factory-set

value

Input range

Remarks

1 Input/output port assignment type

0

Read only 0: Fixed assignment

2

Standard I/O1 fixed assignment:
Initial input port number

000

-1 ~ 599

0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

3

Standard I/O1 fixed assignment:
Initial output port number

300

-1 ~ 599

300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

4

Standard I/O2 fixed assignment:
Initial input port number

32

-1 ~ 599

0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

5

Standard I/O2 fixed assignment:
Initial output port number

316

-1 ~ 599

300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

6

Expansion I/O1 fixed assignment:
Initial input port number
(Network I/F module)

48

-1 ~ 599

0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

7

Expansion I/O1 fixed assignment:
Initial output port number
(Network I/F module)

348

-1 ~ 599

300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

8 Reserved by system

-1

-1 ~ 599

9 Reserved by system

-1

-1 ~ 599

10

Standard I/O1 error monitor

0

0 ~ 5

0: Not

monitored

1: Monitored
2: Monitored (24-V I/O power errors are not

monitored)

3: Monitored. (Only 24-V I/O power errors

are monitored.)

* Some exceptions apply.

11

Standard I/O2 error monitor

0

0 ~ 5

0: Not

monitored

1: Monitored
2: Monitored (24-V I/O power errors are not

monitored)

3: Monitored. (Only 24-V I/O power errors

are monitored.)

* Some exceptions apply.

12

Expansion I/O1 error monitor
(Network I/F module)

1

0 ~ 5

0: Not

monitored

1: Monitored
* Some exceptions apply.

13 Reserved by system

1

0 ~ 5

14

Network I/F card remote input
ports used

64

0 ~ 240

Multiple of 16

15

Network I/F card remote output
ports used

64

0 ~ 240

Multiple of 16

With the TT, the numbers of ProfiBus ports to be used can be changed using the applicable parameters.
The initial ProfiBus I/O port numbers are fixed.
Initial ProfiBus input port number: 48
Initial ProfiBus output port number: 348

The standard I/O (rear panel I/O connector) port numbers are fixed.
Standard input ports: Nos. 16 to 31
Standard output ports: Nos. 316 to 331