IAI America E-Con User Manual
Page 67
7
DEOHWRS5RERW77
59
(2) Factory-set parameters for the TT type
No. Parameter
name
Factory-set
value
Input range
Remarks
1 Input/output port assignment type
0
Read only 0: Fixed assignment
2
Standard I/O1 fixed assignment:
Initial input port number
000
-1 ~ 599
0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)
3
Standard I/O1 fixed assignment:
Initial output port number
300
-1 ~ 599
300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
4
Standard I/O2 fixed assignment:
Initial input port number
32
-1 ~ 599
0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)
5
Standard I/O2 fixed assignment:
Initial output port number
316
-1 ~ 599
300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
6
Expansion I/O1 fixed assignment:
Initial input port number
(Network I/F module)
48
-1 ~ 599
0 + (multiple of 8) (The parameter is invalid if
a negative value is set.)
7
Expansion I/O1 fixed assignment:
Initial output port number
(Network I/F module)
348
-1 ~ 599
300 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
8 Reserved by system
-1
-1 ~ 599
9 Reserved by system
-1
-1 ~ 599
10
Standard I/O1 error monitor
0
0 ~ 5
0: Not
monitored
1: Monitored
2: Monitored (24-V I/O power errors are not
monitored)
3: Monitored. (Only 24-V I/O power errors
are monitored.)
* Some exceptions apply.
11
Standard I/O2 error monitor
0
0 ~ 5
0: Not
monitored
1: Monitored
2: Monitored (24-V I/O power errors are not
monitored)
3: Monitored. (Only 24-V I/O power errors
are monitored.)
* Some exceptions apply.
12
Expansion I/O1 error monitor
(Network I/F module)
1
0 ~ 5
0: Not
monitored
1: Monitored
* Some exceptions apply.
13 Reserved by system
1
0 ~ 5
14
Network I/F card remote input
ports used
64
0 ~ 240
Multiple of 16
15
Network I/F card remote output
ports used
64
0 ~ 240
Multiple of 16
With the TT, the numbers of ProfiBus ports to be used can be changed using the applicable parameters.
The initial ProfiBus I/O port numbers are fixed.
Initial ProfiBus input port number: 48
Initial ProfiBus output port number: 348
The standard I/O (rear panel I/O connector) port numbers are fixed.
Standard input ports: Nos. 16 to 31
Standard output ports: Nos. 316 to 331