IAI America E-Con User Manual
Page 76
5&6&(&RQDQG6&21
68
(5) Monitor LED indications
Of the LEDs provided on the front face of the board, the two LEDs, ERR and POWER, can be used to check
the operating condition of the communication module.
The board has three LEDs, whose conditions and their meanings are explained below.
LED Color Status
Definition
Description
(cause)
Off
Communicating
normally
x The module is operating normally (The module is
connected to the fieldbus and is therefore in
“online” state.)
ERR Red
On
Offline or
communication
error
x The module is not connected to the fieldbus and
is therefore in “offline” state, or a communication
error has occurred.
DIA
Green -
No function
Off
Power Off
x The ProfiBus-DP slave station is not receiving
power.
On
Power ON
x The ProfiBus-DP slave station is receiving
power.
POWER Green
Blinking at 4 Hz Communication
hardware error
x This LED blinks when a communication
hardware error has been detected during the
initialization of the system.