3. X-SEL-J/K/P/Q/JX/KX/PX/QX

14

(2) ProfiBus-DP communication connector interface specifications

This is a 9-pin, female D-sub connector recommended by the ProfiBus-DP standard EN 50170.

Connector

Pin No.

Description

Contents

3 B-Line RxD

x TxD (Positive signal line)

5

GND

Shield

8

A-Line

/RxD

x /TxD (Negative signal line)

Housing

GND

Shield

* Pins 1, 2, 4, 6, 7 and 9 are not used (they need not be wired).

(3) Bus termination settings

Among the units connected to a ProfiBus-DP network, the devices at both ends require termination to prevent
reflected waves from entering the bus line again.
This ProfiBus-DP module provides a termination switch that makes this termination easy.

The user need not install a separate terminal resistor. Never install an additional terminal resistor, as it may
have negative impact on bus communication or cause a communication error, etc.

.

Termination switch ON

Termination enabled
(If this switch is turned ON mistakenly when the module is connected in a position
other than the end of the network, bus communication may be negatively impacted
or a communication error, etc., may result.)

Termination switch OFF

Termination disabled