(6) Input/output (I/O) signal assignments

The RCS-C, E-Con and SCON have the following numbers of inputs and outputs, respectively:
[1] RCS-C 8 dedicated input points, 11 dedicated output points (100/200-V specification) or 10 dedicated

output points (24-V specification)

[2] E-Con

10 dedicated input points, 13 dedicated output

[3] SCON

16 dedicated input points, 16 dedicated output

These inputs and outputs are assigned as shown below.
* For details on each signal, refer to “Operation Manual for RCS Series ROBO Cylinder Controller RCS-C Type,”

“Operation Manual for E-Con Controller” and “Operation Manual for SCON Controller.”

[1] RCS-C

signal

assignments

Input number

Signal name

Output number

Signal name

0

Command position 1

0

Completed position 1

1

Command position 2

1

Completed position 2

2

Command position 4

2

Completed position 4

3

Command position 8

3

Completed position 8

4

Start

4

Positioning complete

5 Reset 5

Home

return complete

6

Servo on

6

Zone

7

*Pause

7

*Alarm

8

Not used

8

*Emergency stop

9

Not used

9

Moving

10

Not used

10

*Battery alarm Note)

11

Not used

11

*Not used

12

Not used

12

*Not used

13

Not used

13

*Not used

14

Not used

14

*Not used

15

Not used

15

*Not used

Note) This signal is available only when the controller’s main power supply specification is 100/200 V.