(1) Name of each part

Pin No.

Signal Name

Description

3

B-Line

Communication Line B (RS485)

4

RTS

Request for Sending

5

GND

Signal Ground (insulated)

6

+5V

+5V output (insulated)

8

A-Line

Communication Line A (RS485)

Housing

Shield

Cable Shield
(connected to housing)

Note 1 1, 2, 7 and 9 pins are not connected.
Note 2 Connector on cable side is not included.

(2) Monitor LED indications

The board operation status and network condition are obtained with the two LEDs located in the front of the
communication board.

ż,OOXPLQDWLQJî2))ڏ Flashing (1Hz)

LED

Color

Indication Status

Indication Description (Detailed Explanation)

Operation

Mode

Green

ż

Online (Communication in normal condition)

ڏ

Online (Cleared)

Orange

ڏ (1Hz)

Parameterizing data error

ڏ (2Hz)

&RQ¿JXUDWLRQHUURU

ņ

î

2QOLQH1RSRZHUVXSSO\FRQ¿UPHG

Status

Green

ż

Initial condition

ڏ

Initial condition (with network check event)

Orange

ż

Exception error

ņ

î

1RSRZHUVXSSO\FRQ¿UPHG
Initializing not executed