4. XSEL-R/S/RX/SX/RXD/SXD

52

4.6 Troubleshooting

1) In case it is not possible to connect the network, check the current condition on the display of monitoring

LEDs of PROFIBUS Board. [Refer to Section 4.2]
Check the settings of the XSEL controller and the settings of the master unit referring to the instruction
manuals of the master unit.

2) When an alarm is issued, an alarm code gets output to the panel window of the XSEL controller.

(1) Find the alarm code that you see on the window from the alarm code list shown below.

Deal with it based on the description for the alarm code in question.

(2) In case the alarm code is not found in the following list, search in the alarm contents list contained in XSEL

Controller Instruction Manual. Deal with it based on the description for the alarm code in question.

Alarm Code (Fieldbus related items are chosen below)

No.

Error name

Contents and Treatment

678

Extended I/O Port Assignment Parameter
Error

There is an error in a parameter related to the extended I/O port
assignment.

679

Extended I/O Port Assignment Number
2YHUÀRZ(UURU

The number of extended I/O port assignment exceeded the
VSHFL¿FDWLRQUDQJH

67A

Extended I/O Port Duplicated Assignment
Error

Extended I/O port assignment has duplicated.

D56

Fieldbus error
(MinACK Timeout)

An error was detected in the communication board.
Check the condition of PLC, and reboot the XSEL controller unless
there is an error. If the same error occurs again, please contact us.

D59

Fieldbus error
(DPRAM writing and reading)

The writing and reading error was detected in the internal memory.
XSEL Controller reboot the controller. If the same error occurs again,
please contact us.

D5A

Fieldbus error
(TOGGLE Timeout)

A communication board error was detected.
XSEL Controller reboot the controller. If the same error occurs again,
please contact us.

D5B

Fieldbus error
(Access right retry over)

A communication board error was detected.
XSEL Controller reboot the controller. If the same error occurs again,
please contact us.

D5D

Fieldbus error
(FBRS link error)

This occurs when the network connection is not established.
1) Check the station number, the parameters for communication

speed and parameters on PLC side.

2) It is concerned the startup of XSEL is faster than that of PLC.

Change the settings in I/O Parameter No. 120.
[Refer to Section 4.3 (7) for the details.]

D5E

Fieldbus error
(Mail BOX response)

A communication board error was detected.
Reboot the XSEL controller. If the same error occurs again, please
contact us.

D5F

Network I/F Module Class Mismatch
Error

The setting of I/O Parameter No. 225 Network I/F Module Class does
not match with that of the communication board currently mounted to
XSEL.
Check the contents of the settings in I/O Parameter No. 225, and in
case no doubt is found, please contact us.

D75

Fieldbus Parameter Error

There is an error in a parameter.
Check I/O Parameter No. 226 to 227 and 237 to 238.
Example)

xA node address out of the range was set.
x A baud rate out of the range is set.