Page 26

background image

3. X-SEL-J/K/P/Q/JX/KX/PX/QX

18

3.3.2 Factory-set Parameters (Default Settings)
(1) Factory-set parameters for the J/K/JX/KX types

x I/O

Parameter

Settings

No.

Parameter name

Input range

A B C

Remarks

1

Input/output port assignment type

0 ~ 20

0

0

0

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 ~)

* Ports are assigned automatically only

for the contiguous slots in use, starting
from slot 1 = For safety reasons.

2

Standard I/O fixed assignment:
Initial input port number (I/O1)

-1 ~ 599

000

000

-1

0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

3

Standard I/O fixed assignment:
Initial output port number (I/O1)

-1 ~ 599

300

300

-1

300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)

4

Expansion I/O1 fixed assignment:
Initial input port number (I/O2)

-1 ~ 599

-1

-1

-1

0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
(Slot next to standard I/O)

5

Expansion I/O1 fixed assignment:
Initial output port number (I/O2)

-1 ~ 599

-1

-1

-1

300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)

6

Expansion I/O2 fixed assignment:
Initial input port number (I/O3)

-1 ~ 599

-1

-1

000

0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

7

Expansion I/O2 fixed assignment:
Initial output port number (I/O3)

-1 ~ 599

-1

-1

300

300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)

8

Expansion I/O3 fixed assignment:
Initial input port number (I/O4)

-1 ~ 599

-1

-1

-1

0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)

9

Expansion I/O3 fixed assignment:
Initial output port number (I/O4)

-1 ~ 599

-1

-1

-1

300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)

10 Standard I/O error monitor

0 ~ 5

2

2

2

0: Not monitored

11 Expansion I/O1 error monitor

0 ~ 5

0

0

0

1: Monitored

12

Expansion I/O2 error monitor

0 ~ 5

0

0

2

2: Monitored (24-V I/O power errors are

not monitored)

(Main application version 0.55 or later)

13

Expansion I/O3 error monitor

0 ~ 5

0

0

0

3: Monitored (only 24-V I/O power errors

are not monitored).

(Main application version 0.55 or later)

14

Network I/F card remote input
ports used

0 ~ 256

64

64

64

Multiple of 8

15

Network I/F card remote output
ports used

0 ~ 256

64

64

64

Multiple of 8