IAI America E-Con User Manual
Page 26
3. X-SEL-J/K/P/Q/JX/KX/PX/QX
18
3.3.2 Factory-set Parameters (Default Settings)
(1) Factory-set parameters for the J/K/JX/KX types
x I/O
Parameter
Settings
No.
Parameter name
Input range
A B C
Remarks
1
Input/output port assignment type
0 ~ 20
0
0
0
0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 ~)
* Ports are assigned automatically only
for the contiguous slots in use, starting
from slot 1 = For safety reasons.
2
Standard I/O fixed assignment:
Initial input port number (I/O1)
-1 ~ 599
000
000
-1
0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
3
Standard I/O fixed assignment:
Initial output port number (I/O1)
-1 ~ 599
300
300
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
4
Expansion I/O1 fixed assignment:
Initial input port number (I/O2)
-1 ~ 599
-1
-1
-1
0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
(Slot next to standard I/O)
5
Expansion I/O1 fixed assignment:
Initial output port number (I/O2)
-1 ~ 599
-1
-1
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
6
Expansion I/O2 fixed assignment:
Initial input port number (I/O3)
-1 ~ 599
-1
-1
000
0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
7
Expansion I/O2 fixed assignment:
Initial output port number (I/O3)
-1 ~ 599
-1
-1
300
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
8
Expansion I/O3 fixed assignment:
Initial input port number (I/O4)
-1 ~ 599
-1
-1
-1
0 + (multiple of 8) (The parameter is invalid
if a negative value is set.)
9
Expansion I/O3 fixed assignment:
Initial output port number (I/O4)
-1 ~ 599
-1
-1
-1
300 + (multiple of 8) (The parameter is
invalid if a negative value is set.)
10 Standard I/O error monitor
0 ~ 5
2
2
2
0: Not monitored
11 Expansion I/O1 error monitor
0 ~ 5
0
0
0
1: Monitored
12
Expansion I/O2 error monitor
0 ~ 5
0
0
2
2: Monitored (24-V I/O power errors are
not monitored)
(Main application version 0.55 or later)
13
Expansion I/O3 error monitor
0 ~ 5
0
0
0
3: Monitored (only 24-V I/O power errors
are not monitored).
(Main application version 0.55 or later)
14
Network I/F card remote input
ports used
0 ~ 256
64
64
64
Multiple of 8
15
Network I/F card remote output
ports used
0 ~ 256
64
64
64
Multiple of 8