49

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

10

Standard I/O Error Monitoring
(I/O1)

1

0 to 5

1

0:No Monitoring (Not to use I/O board)
1:Monitoring
2:Monitoring (Not to monitor 24V I/O power

related error)

3:Monitoring (To monitor only 24V I/O

power related error)

14

No. of Network I/F Module 1
Remote Input Ports

0

0 to 256

0

8 port unit

15

No. of Network I/F Module 1
Remote Output Ports

0

0 to 256

0

8 port unit

16

Input Port Start No. in Network I/F
Module Fix-Allocated

-1

-1 to 599

-1

0+ (Multiples of 8)
[Ineffective when -1 is selected]

17

Output Port Start No. in Network
I/F Module Fix-Allocated

-1

-1 to 599

-1

300+ (Multiples of 8)
[Ineffective when -1 is selected]

18

Network I/F Module 1
Error Monitoring

1

0 to 5

0

0:No Monitoring

(Not to use Network I/F Module 1)

1:Monitoring

120 Network attribute 1

640001H

0 to

FFFFFFFFH

Optional

Bits 16 to 23:
Value of Link Timeout at initializing
(Example) Default 64H = 10sec

121 Network attribute 2

0H

0 to

FFFFFFFFH

Optional

Bits 8 to 15:
Input port data selected at Network I/F
Module 2 link error

0:Input port data clear
1:Input port data retained

225 Network I/F Module Control

3*

00H to 37H

30

Bits 0 to 3:
Network I/F Module 1 type

0:Not Mounted
6:EtherCAT
7:EtherNet/IP

Bits 4 to 7:
Network I/F Module 2 type

0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS

231

No. of Network I/F Module 2
Remote Input Ports

0

0 to 256

192

8 port unit

232

No. of Network I/F Module 2
Remote Output Ports

0

0 to 256

192

8 port unit

233

Extension Input Port Start No.
at Network I/F Module 2 Fixed
Assignment

-1

-1 to 299

1000 to 3999

0

0+ (Multiples of 8)
or
1000+ (Multiples of 8)
[Ineffective when -1 is selected]

234

Extension Output Port Start No.
at Network I/F Module 2 Fixed
Assignment

-1

-1

300 to 599

4000 to 6999

300

300+ (Multiples of 8)
or
4000+ (Multiples of 8)
[Ineffective when -1 is selected]

235

Network I/F Module 2
Error Monitoring

1

0 to 5

1

0:No Monitoring (Not to monitor condition

of link to PLC (master))

1:Monitoring

237

Network I/F Module 2
Node Address

0

0 to 125

Optional PROFIBUS node address range: 0 to 125

This manual is related to the following products: